Site Manager Parameters
308623-14.00 Rev 00
A-13
Parameter: BofL Enable
Path: Configuration Manager > XCVR Connector > Edit Line
Default: Enable
Options: Enable
|
Disable
Function: When this parameter is set to Enable, the router sends BofL polling messages
from this system to all systems on the local network.
Instructions: Set to Enable or Disable. We recommend that you enable BofL.
MIB Object ID: 1.3.6.1.4.1.18.3.4.1.1.7
Parameter: BofL Timeout
Path: Configuration Manager > XCVR Connector > Edit Line
Default: 5 (4 if router redundancy is enabled)
Options: 1 to 60 seconds
Function: Specifies the time between transmissions of Breath of Life messages from this
Ethernet interface. Timeout will occur if five periods elapse without a successful
BofL message transmission. When timeout occurs, the router disables and
reenables the Ethernet interface.
This parameter is valid only if you set BofL Enable to Enable.
Instructions: Accept the default BofL timeout of 5 seconds, or specify a new value up to 60
seconds.
MIB Object ID: 1.3.6.1.4.1.18.3.4.1.1.8