Configuring Ethernet, FDDI, and Token Ring Services
3-12
308623-14.00 Rev 00
• Detects duplicate MAC addresses on the ring
• Generates periodic “keepalive” traffic that verifies the local MAC transmit
and receive paths
Using the BCC
To set the neighbor notification interval, access an existing FDDI line service and
enter:
neighbor-notify-time
<integer>
integer
is the neighbor notification interval value expressed in seconds. You can
enter any integer value from 2 to 30.
For example, to set the neighbor notification interval to 10, enter the following
command sequence:
box# fddi slot 11 connector 1
fddi/11/1# neighbor-notify-time 10
Using Site Manager
To set the neighbor notification interval, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a
FDDI
Connector
.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit FDDI Parameters window
opens.
3. Choose
Expert
. The FDDI Advanced Attributes window
opens.
4. Choose
SMT Attributes
. The FDDI SMT Attributes window opens.
5. Set the
T_Notify Timeout
parameter.
Click on
Help
or see the parameter
description on page A-20.
6. Click on
OK
. You return to the FDDI Advanced
Attributes window.
7. Click on
Done
. You return to the Edit Connector window.
8. Click on
Done
. You return to the Configuration Manager
window.
Kommentare zu diesen Handbüchern