Parameter: Flow Control Pause Time
Path: Configuration Manager > XCVR Connector > Edit Line
Default: 65535
Options:
32 to 65535 pause times
Function:
Specifies the flow control pause time. The pause time is used to calculate the
total time a transmitter pauses. For example, when a transmitter receives a pause
frame, it pauses for
pause_time
* 512 bit times. (The value 512 bit times
converts to 51.2 ms for 10 Mb/s, 5.12 ms for 100 Mb/s, and 512 ns for Gigabit.)
Therefore, if the pause time is 65535 and the line speed is 100 Mb/s, then the
transmitter pauses for 335.54 ms (65535 * 5.12 ms).
Instructions:
Accept the default, 65535, or specify a value from 32 to 65535.
MIB Object ID:
1.3.6.1.4.1.18.3.4.1.1.67
Parameter: Transmit Pause Zero Enable
Path:
Configuration Manager > XCVR Connector > Edit Line
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables the ability of a congested receiver to send a pause frame
with a pause time of 0 when it is no longer congested. When the remote
transmitter receives a pause frame with a 0 pause time, it resumes sending
packets.
Instructions: Accept the default, Enable, if you want a congested receiver to send a pause
frame with a pause time of 0 when it is no longer congested. Choose Disable if
you do not want a congested receiver to send a pause frame with a 0 pause time.
MIB Object ID: 1.3.6.1.4.1.18.3.4.1.1.68