Installing a Wallboard
Chapter 5
Installing the Wallboard 5-3
Installing the Wallboard 5
To install an external wallboard to use with BCMS Vu software, complete the
following tasks:
Unpack the wallboard.
Be sure that a converter box that converts the communication protocol
from RS-485 (the wallboard protocol) to RS-232 (the PC protocol) is
included with the wallboard.
Be sure that the wallboard installation document is included with the
wallboard.
Connect the communications cable from the wallboard to the PC.
If the serial port on the PC has 25 pins, use a DB25-to-RJ11
connection cable.
If the serial port on the PC has 9 pins, use a DB9-to-RJ11 connection
cable.
For complete instructions on how to install Lucent wallboards, refer to the
manuals listed on the first page of this document.
For instructions on how to install other types of wallboards, refer to the
user’s manual that accompanies the wallboard.
Note
Lucent wallboards are addressed using hexadecimal
notation. You address them using the remote control unit
that comes with the wallboards. Refer to the user’s guide
that comes with the wallboard.
However, when you enter a wallboard address in the BCMS
Vu configuration procedure, you must use decimal notation.
Furthermore, BCMS Vu accepts wallboard addresses only
from 0 to 127 (decimal).
The table at the end of this chapter relates decimal addresses
from 0 to 127 to corresponding hexadecimal addresses.