Installing the Data Module, Hardware Key, and Remote Maintenance Line
3-16 Installing the Data Module
Installing an 8400B Plus Data Module without a
Telephone
3
The 8400B Plus options must be set with a terminal (715 BCS system
administration terminal) or PC with terminal emulation.
Windows NT 4.0 come with HyperTerminal. To access it,
1. Click on Start/Programs/Accessories/Hyperterminal/HyperTerm.
2. Enter test in the “name” field.
3. Select OK.
4. Change “connect using” to direct to COM 1, COM 2, COM 3, and so
forth, depending on which COM Port you are using to connect to
the data module.
5. Select OK until you get a blank screen.
Issue the following commands:
Command Response
1. at OK (This indicates a good connection between the ter-
minal/PC and the 8400B Plus.)
2. at&f OK (This resets to factory default settings.)
3. ats24? 000 (Default setting.)
4. ats24=001 001 OK (This indicates that the option has been changed
to “without a voice telephone.”)
5. at&w0 OK (Options are stored in profile 0.)
6. at&y0 OK (Profile 0 is designated to be used in case the 8400B
Plus loses power.)
Power Up 3
When you first apply power to the 8400B Plus, the unit carries out a self-test
to verify that it is in working order. During the self-test, both LEDs will
remain lit. When the self-test is complete, the green LED will go off.
If the self-test passed, the red LED will remain lit. This indicates that the unit
is installed and ready for use.
Kommentare zu diesen Handbüchern