Configuring ATM Half-Bridge Services
A-2
308611-14.00 Rev 00
Instructions for setting the parameter
Management information base (MIB) object ID
The Technician Interface allows you to modify parameters by issuing
set and
commit commands with the MIB object ID. This process is equivalent to
modifying parameters using Site Manager. For more information about using the
Technician Interface to access the MIB, refer to Using Technician Interface
Software.
AHB Global Parameters
Use the following guidelines to configure AHB global parameters in the Edit
ATM Half-Bridge Global Parameters window (Figure A-1
). The Edit ATM
Half-Bridge Global Parameters window contains parameters that allow you to
customize AHB operation.
Figure A-1. Edit ATM Half-Bridge Global Parameters Window
Caution:
The Technician Interface does not verify the validity of your
parameter values. Entering an invalid value can corrupt your configuration.