Avaya Configuring ATM Services Bedienungsanleitung Seite 139

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 426
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 138
Customizing Signaling
308612-14.00 Rev 00
4-23
Using the BCC
To change a timer value, navigate to the signaling timers prompt (for example,
box; atm/11/1; signaling/11/1; timers/11/1) and enter:
<timer_name>
<integer>
timer_name
is the BCC name for the timer (see Table 4-1 for the names and
descriptions of signaling timers).
integer
is the time value (in seconds) that you want the timer to use.
For example, the following command changes the disconnect timer to 8 seconds:
timers/11/1# disconnect-timer 8
timers/11/1#
Using Site Manager
To change a signaling timer value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM 1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
ATM Signaling
. The ATM Signaling Parameters window
opens.
(continued)
Seitenansicht 138