Configuring ATM Services
7-32
308612-14.00 Rev 00
Modifying LEC Timers and Retry Counters
You can modify the following timers and counters for each LEC:
Control timeout
VCC timeout period
Maximum retry count
Aging time
Forward delay time
Expected LE_ARP response time
Path switching delay
Setting the Control Timeout
The control timeout parameter specifies the timeout period used for most request/
response control frame interactions. The default timeout is 5 seconds, but you can
set it to any value from 5 to 32,767 seconds.
Using the BCC
To change the control timeout, navigate to the service record prompt (for example,
box; atm/11/1; lec-service/newyork
) and enter:
control-timeout
<value>
value
is the timeout period you want the LEC to use for control frame interactions.
For example, the following command changes the control timeout to 10 seconds:
lec-service/newyork#
control-timeout 10