Configuring ATM Services
A-60
308612-14.00 Rev 00
Parameter: T397
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 180
Options: 180 to 1024
Function: Specifies the Alerting Received timer value (in seconds). This timer begins
when the circuit sends an ALERTING or ADD PARTY ALERTING message to
a party (the receiver of the message) on the network.
The Alerting Received timer stops when the circuit receives a DROP PARTY
ACKNOWLEDGE message (indicating that the end point used for the party has
been released) or a RELEASE message (indicating that the end point used for
the party has been released and there are no remaining parties).
This timer can be used with UNI Version 4.0 and later.
Instructions: Accept the default, 180, or enter a value from 180 to 1024.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.43