Avaya Configuring ATM Services Bedienungsanleitung Seite 359

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 426
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 358
Site Manager Parameters
308612-14.00 Rev 00
A-61
Parameter: T398
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 24
Function: Specifies the Drop Party Sent timer value (in seconds). This timer applies to
multipoint connections only and begins when the circuit sends a DROP PARTY
message to a party (the receiver of the message) on the network.
The Drop Party Sent timer stops when the circuit receives a DROP PARTY
ACKNOWLEDGE message (indicating that the end point used for the party has
been released) or a RELEASE message (indicating that the end point used for
the party has been released and there are no remaining parties).
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.34