Configuring Dial Services
13-4
308621-14.00 Rev 00
For more information about using the BCC to configure frame relay, see
Configuring Frame Relay Services.
Using Site Manager
To configure a PPP backup circuit for a frame relay PVC:
Site Manager Procedure
You do this System responds
1. Configure a frame relay leased interface
with a service record containing one PVC.
You need to add a new service record to
the frame relay interface. When you add a
service record, it automatically has only
one PVC, which requires a DLCI number.
For instructions, see
Configuring Frame
Relay Services
.
2. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
3. Choose
Backup Circuits
. The Backup Circuits menu opens.
4. Choose
PPP
. The Primary Circuit Definition window
opens, listing the frame relay PVC.
5. Select the frame relay circuit and click on
Cct Type
.
The Circuit Options window opens.
6. Set the
Circuit Type
parameter to
Primary
. Click on
Help
or see the
parameter description on page A-78.
7. Set the
Backup Pool ID
parameter. Click
on
Help
or see the parameter description
on page A-68.
8. Click on
OK
. You return to the completed Primary
Circuit Definition window.
9. Repeat steps 5 through 8 for each primary
circuit that you want to add.
10. Click on
Done
. You return to the Configuration Manager
window.