Configuring Line Services
6-12
Parameter: Setup Alarm Threshold (seconds)
Default: 2 seconds
Range: 2 to 10 seconds
Function: Specifies the time interval during which MCT1 tolerates a performance
defect or anomaly. If the performance defect or anomaly is still present
when this time interval expires, MCT1 records a performance failure and
logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.7
Parameter: Clear Alarm Threshold (seconds)
Default: 2 seconds
Range: 2 to 10 seconds
Function: Specifies the clear time for performance failure conditions. If the defect or
anomaly clears within this time interval, MCT1 records a
performance-cleared condition and logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.8
Parameter: FDL Configuration
Default: ANSI 403
Options: ANSI 403
| AT&T 54016 | None
Function: Selects a Facility Data Link (FDL) mode only when the line is configured
with an ESF line type. The default, ANSI 403 mode, conforms to the 1989
ANSI T1.403 specification (Carrier-to-Customer Installation DS1
Metallic Interface); AT&T 54016 conforms to the 1989 AT&T
specification (Requirements for Interfacing Digital Terminal Equipment
to Services Employing the Extended Superframe Format).
Instructions: Specify the operational mode.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.4.1.14