Customizing Line Protocols
3-43
Parameter: Enable
Default: Enable
Options: Enable
| Disable
Function: Enables or disables the ATM circuit for this connector.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.1.1.2
Parameter: Data Path Notify
Default: Enable
Options: Enable
| Disable
Function: Enables or disables the Data Path Notify function, which disables the data
path interface when the physical interface becomes non-operational.
Instructions: Accept the default, Enable, if you want to disable the data path interface
when the physical interface becomes non-operational. Select Disable if
you do not want the router to disable the data path interface when the
physical interface becomes non-operational.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.1.1.14
Parameter: Data Path Notify Timeout
Default: 3 seconds
Range: 0 to 3600 seconds
Function: Specifies the number of seconds to wait before implementing the Data
Path Notify function. When the Data Path Notify parameter is set to
Enable, Site Manager sets a timer to this value when the state of the
physical interface changes from operational to non-operational.
Instructions: Either accept the default value, 3 seconds, or specify a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.1.1.15