Avaya Configuring Dial Services Bedienungsanleitung Seite 175

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 326
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 174
Configuring Demand Circuits
114062 Rev. A
8-11
Parameter: Maximum Up Time
Default: 60 minutes
Range: 1 to 999999 minutes
Function: Specifies the maximum duration of a call for a continuous period of time.
By configuring this parameter, you ensure that the connection is not up
longer than necessary.
For example, you may configure the circuit’s availability (via the Start
and End time parameters) from 9:00 a.m. to 5:00 p.m. Then configure this
parameter for 60 minutes. If the connection comes up at 10:00 a.m., the
router keeps the circuit active until 11:00 a.m. Then the router invokes the
Max UpTime Termination parameter to deactivate the circuit.
Instructions: Enter the maximum amount of time the call can last for a continuous time
period.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.10
Parameter: Max UpTime Termination
Default: Disabled
Options: Enabled
|
Disabled
Function: Automatically brings down the circuit if the call reaches the maximum
time that you specify in the Maximum Up Time parameter. If the router
receives data after the circuit is down, the router does not establish a
demand connection.
Instructions: Enter Enable if you want the circuit to terminate upon reaching the
maximum time limit for the call.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.33
Seitenansicht 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 325 326

Kommentare zu diesen Handbüchern

Keine Kommentare