Customizing SAAL
114056 Rev. A 12-3
No
Response
Timer
70 1 through 120 Defines the SSCOP No Response Timer value (in tenths of a
second). This value sets the allowable time between the
receipt of STAT PDUs.
So as not to interrupt the flow of data, the SSCOP does not
require a reply to every POLL PDU. This can cause problems
in detecting a broken connection. To alleviate this problem, the
No Response timer runs parallel to the poll timer. If both the
No Response timer and the poll timer expire, the SSCOP
clears the connection.
The No Response Timer value must equal at least the sum of
the Keep Alive Timer plus the length of one round-trip delay.
Connection
Control
Timer
10 1 through 120 Defines the SSCOP Connection Control (CC) Timer value (in
tenths of a second). This value sets the allowable time
between the transmission of BGN, END, resynchronization
(RS), and error recovery (ER) PDUs, as long as the sender
has not received an acknowledgment to any of these PDUs.
The CC Timer must equal at least the length of one round-trip
delay.
Site Manager: Poll Timer: page A-62
Site Manager: Keep Alive Timer: page A-62
Site Manager: No Response Timer: page A-63
Site Manager: Connection Control Timer: page A-63
Table 12-1. Signaling Timer Descriptions
(continued)
Name Default Range Description