Site Manager Parameters
114056 Rev. A A-63
Parameter: No Response Timer
Path: Configuration Manager > Protocols > ATM > Signaling AAL
Default: 70
Options: 1 through 120
Function: Defines the SSCOP No Response Timer value (in tenths of a second). This value
sets the allowable time between the receipt of STAT PDUs.
So as not to interrupt the flow of data, the SSCOP does not require a reply to
every POLL PDU. This can cause problems in detecting a broken connection.
To alleviate this problem, the no response timer runs parallel to the poll timer. If
both the no response timer and the poll timer expire, the SSCOP clears the
connection.
The No Response Timer value must equal at least the sum of the keep alive
timer plus the length of one round-trip delay.
Instructions: Accept the default, 70, or enter a value from 1 through 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.11
Parameter: Connection Control Timer
Path: Configuration Manager > Protocols > ATM > Signaling AAL
Default: 10
Options: 1 through 120
Function: Defines the SSCOP Connection Control Timer value (in tenths of a second).
This value sets the allowable time between the transmission of BGN, END,
resynchronization (RS), and error recovery (ER) PDUs, so long as the sender
has not received an acknowledgment to any of these PDUs.
The CC timer must equal at least the length of one round-trip delay.
Instructions: Accept the default, 10, or enter a value from 1 through 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.12