Site Manager Parameters
114056 Rev. A A-47
Parameter: T316
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 120
Options: 1 through 720
Function: Defines the Restart Request Sent on Interface timer value (in seconds). This
timer begins when the circuit sends a RESTART message to the network. The
circuit uses the RESTART message to return all VCs on the interface to the idle
condition.
The Restart Request Sent on Interface timer stops when the circuit receives a
RESTART ACKNOWLEDGE message from the network.
If the timer expires before the circuit receives a RESTART ACKNOWLEDGE
message, the circuit can transmit as many RESTART messages as specified with
the Num Restarts ReXmitted parameter (refer to the parameter description later
in this section). If the circuit still does not receive a response, the circuit enters
the Null state until the appropriate maintenance action is taken.
Instructions: Accept the default, 120, or enter a value from 1 through 720.