Site Manager Parameters
114056 Rev. A A-5
ATM Line Parameter Descriptions
The type of ATM link module you use determines what line details you must edit.
Figure A-1 shows the window sequence for the line attributes category.
Figure A-1. Line Attributes Window Sequence
ATM FRE2 Line Details
This section describes how to edit the line details for ATM FRE2 link modules.
Parameter: Enable
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: Enable
Options: Enable
| Disable
Function: Enables or disables the ATM circuit for this connector.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.1.1.2
Line Attributes
ATM/ARE Line Driver
Attributes window
Edit ATM Connector window
OK
Done
Configuration Manager
window