Configuring ATM Services
B-4 114056 Rev. A
ATM FRE2 Line Parameters
ATM ARE Line Parameters
Table B-8. ATM FRE2 Line Parameters
Parameter Default
Enable Enable
Data Path Notify Enable
Data Path Notify Timeout 3 s
SVC Inactivity Timeout Enable Enable
SVC Inactivity Timeout (Secs) 1200 s
Table B-9. ATM FRE2 Physical Attribute Parameters
Parameter Default
Framing Mode SONET
Scrambling Enable
Loopback Disable
Cell Insertion Unassigned
Table B-10. ATM ARE Line Parameters
Parameter Default
Enable Enable
Interface MTU 4608
Data Path Enable Enable
Data Path Notify Timeout 1 s
SVC Inactivity Timeout Enable Enable
SVC Inactivity Timeout (Secs) 1200 s
Framing Mode SONET
Clocking Signal Source Internal