Configuring DECnet Services
3-6
308619-14.00 Rev 00
Parameter: Max Broadcast Non Routers
Default: 64
Options: 0 to 1023
Function: Specifies the maximum number of end node adjacencies residing on all
circuits for a single slot. The higher the number of adjacent end nodes, the
greater the impact on the router’s performance and memory use.
Instructions: Consult your network topology drawing. If there are more than 64 end
node adjacencies on any of the router’s slots, increase this number to
reflect your network topology.
MIB Object ID: 1.3.6.1.4.1.18.3.5.2.1.7
Parameter: Max Broadcast Routers
Default: 32
Options: 0 to 1023
Function: Specifies the maximum number of router adjacencies on all circuits for a
single slot.
Instructions: Consult your network topology drawing. If there are more than 32 router
adjacencies on any of the router’s slots, increase this number to reflect
your network topology. Decrease this number if there are fewer than 32
router adjacencies on a single slot.
MIB Object ID: 1.3.6.1.4.1.18.3.5.2.1.8
Parameter: Max Circuits
Default: 1024
Options: 1 to 1024
Function: Specifies the highest circuit number that this router can recognize, that is,
the maximum number of circuits that this router can recognize.
Instructions: We recommend accepting the default value.
MIB Object ID: 1.3.6.1.4.1.18.3.5.2.1.9