Configuring DLSw Services
5-12
Parameter: Maximum Package Size
Default: 1532 bytes
Range: 0 to 2147483647
Function: Specifies the maximum package size (in bytes) when sending multiple
DLSw frames in a single TCP frame for transmission over a wide area
network.
Instructions: Specify a value smaller than the TCP Window Size parameter and less
than or equal to the Virtual Ring MTU size for the network minus the size
of the TCP/IP and MAC headers.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.1.23
Parameter: Packaging Timeout
Default: 10 milliseconds (ms)
Range: 0 to 2147483647
Function: Specifies the time interval (in milliseconds) to delay a package before
sending it to TCP. This value is based on the Packaging Threshold
parameter. The value should not be greater than the time it takes to send
the number of outstanding bytes before packaging begins.
Instructions: Type any positive integer in the range 0 to 2147483647. Values are in
milliseconds.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.1.24
Parameter: Packaging Threshold
Default: 20 percent of the TCP window size
Range: 0 to 100 percent (0 indicates no delay)
Function: Specifies the percentage of the DLSw TCP window that must be in use if
DLSw is to delay sending a package (one that is currently being built).
Instructions: Type a value in the range 0 to 100 percent. A value of 20 percent indicates
that if 20 percent of the TCP window size is being used, DLSw issues the
delay, as specified by the Packaging Timeout parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.1.25