Configuring DLSw Services
5-14
Following is a description of the parameters in the DLSw Interface Configuration
window.
Parameter: Enable
Default: Enable
Options: Enable | Disable
Function: Enables or disables Data Link Switching over this interface.
Enable — Initializes the DLSw interface you added to a physical circuit.
Also use the Enable setting to reinitialize an existing DLSw interface
disabled earlier. The state of the interface depends on the up/down state of
the associated circuit and slot.
Disable — Switches a DLSw interface from the enabled (up) state to the
disabled (down) state.
Instructions: Select Enable if you previously set this parameter to Disable and now
want to re-enable Data Link Switching over this interface.
Select Disable only if you want to disable Data Link Switching over this
interface. This cancels all active LLC2 sessions currently supported by
the interface.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.2.1.2
Enabling a DLSw Interface Using the Edit Circuits Function
You can also access the Enable parameter of a DLSw interface through the Edit
Circuits function. To do so, begin at the Configuration Manager window (refer to
Figure 5-1), and do either of the following:
• Select Circuits➔Edit Circuits to bring up the Circuit List window
(Figure 5-4); then select a circuit and click on Edit.
• Select a connector in the Configuration Manager window to invoke the Edit
Connector window (Figure 5-5); then click on Edit Circuit.