Configuring HSSI Services
308648-14.00 Rev 00
5-7
Using the BCC
To set external clock speed, navigate to the hssi prompt (for example,
box
;
hssi/2/1
) and type:
external-clock-speed
integer
For example:
hssi/2/1#
external-clock-speed 46359642
Using Site Manager
See the External Clock Speed parameter on page A-15 for information.
Setting the CRC Size
The CRC Size parameter specifies an error-detection scheme. Choose either 16 bit
(standard ITU-T) or 32 bit (extended) to detect errors in the packet. The remote
end of the HSSI connection must be configured for the same CRC size.
Set the CRC size for this HSSI interface.
Using the BCC
To set the CRC size, navigate to the hssi prompt (for example,
box
;
hssi/2/1
) and
type:
crc-size
variable
For example:
hssi/2/1#
crc-size crc32bit
hssi/2/1#
crc-size crc16bit
Using Site Manager
See the CRC Size parameter on page A-16 for information.