Configuring WAN Line Services
7-6
308648-14.00 Rev 00
Using the BCC
To set the clock parameters, navigate to the mct1/1/1 prompt (for example,
box
;
mct1/1/1
) and type:
primary-clock
variable
secondary-clock
variable
For example:
mct1/1/1#
primary-clock internal
mct1/1/1#
secondary-clock internal
Using Site Manager
To set the clock parameters, complete the following tasks.
You access the Edit Clock Parameters window based on which link or net module
you are configuring, and whether you have already configured the port:
• Newly installed Single- or Dual-Port MCE1 or MCT1 link module
The Edit DS1E1 Clock Parameters window opens automatically the first time
you configure an interface.
• Configured Single- or Dual-Port MCE1 or MCT1 link or net module
Click on the CLOCK connector for the MCE1 or MCT1 module on the
Configuration Manager window.
• Newly installed DMCT1 net module, QMCT1 link module, or
QMCT1 w/DS0A link module.
Site Manager Procedure
You do this System responds
1. In the Edit Clock Parameters window,
select a primary clock source option.
2. Select the secondary (backup) clock
source option.
3. Click on
OK
. The MCE1 Port Parameters window or
MCT1 Port Parameters window opens.