Parameter: Setup Alarm Threshold (seconds)
Path: FE1 Connector > Adapter Module FE1 Logical Lines > Port Details > Edit
Adapter Module FE1 Port Parameters
Default: 2 seconds
Options: 2 to 10 seconds
Function: Specifies the time, in seconds, that the device driver tolerates a performance
defect or anomaly. If the performance defect or anomaly is still present when
this time interval expires, the device driver records a performance failure and
logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.7
Parameter: Clear Alarm Threshold (seconds)
Path: FE1 Connector > Adapter Module FE1 Logical Lines > Port Details > Edit
Adapter Module FE1 Port Parameters
Default: 2 seconds
Options: 2 to 10 seconds
Function: Specifies the clear time, in seconds, for performance-failure conditions. If the
defect or anomaly clears in this time interval, the device driver records a
performance-cleared condition and logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.8
Parameter: Accept Loopback Request
Path: FE1 Connector > Adapter Module FE1 Logical Lines > Port Details > Edit
Adapter Module FE1 Port Parameters
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables loop-up and loop-down code detection. When this
parameter is enabled, this port accepts and complies with requests to go into
loopback mode from a remote device.
Instructions: Enable or disable local loopback.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.10