Configuring WAN Line Services
B-62
308648-14.00 Rev 00
The output contains the following information:
Slot/Conn Slot location of the MCT1/MCE1 module within the
chassis and the connector number.
Circuit Name of the circuit associated with this line.
State State of the line driver: Down, Init (initializing), Not
Present (enabled but not yet started), or Up.
The Not Present state occurs for several reasons. For
example, the link module may not be physically present in
the chassis; the software may be booting and has not yet
initialized the driver software; the slot may be running
diagnostics; or there may be a problem with the
configuration.
Errors:
Receive Number of receive errors.
Transmit Number of transmit errors.
Bytes:
Receive Number of octets received without error.
Transmit Number of octets transmitted without error.
Frames:
Receive Number of frames received without error.
Transmit Number of frames transmitted without error.
Avg. Pkt.:
Receive Average packet size (number of bytes divided by number
of frames) received without error.
Transmit Average packet size (number of bytes divided by number
of frames) transmitted without error.
Multicast
Receive Number of packets received that are not unicast packets.
Kommentare zu diesen Handbüchern