Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-21
Setting the Alarm Threshold Time
By default, the MCT1 interface waits 2 seconds before logging a performance
defect or anomaly as an event message. Change the alarm threshold time to any
value from 2 to 10 seconds.
Using the BCC
To change the alarm threshold time, navigate to the mct1 prompt (for example,
box
;
mct1/1/1
) and type:
setup-alarm-threshold
integer
For example:
mct1/1/1#
setup-alarm-threshold 3
Using Site Manager
See the Setup Alarm Threshold (seconds) parameter on page A-31 for
information.
Setting the Alarm Threshold Clear Time
By default, the clear time for performance-failure conditions is 2 seconds.
If the defect or anomaly clears in this time interval, MCT1 records a
performance-cleared condition and logs an event message. You can change
the alarm threshold clear time to any value from 2 to 10 seconds.
Using the BCC
To set the alarm threshold clear time, navigate to the mct1 prompt (for example,
box
;
mct1/1/1
) and type:
clear-alarm-threshold
integer
For example:
mct1/1/1#
clear-alarm-threshold 3
Using Site Manager
See the Clear Alarm Threshold (seconds) parameter on page A-32
for information.