Avaya Configuring BayStack Remote Access Bedienungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 140
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
Configuring BayStack Remote Access
1-8
308614-14.00 Rev 00
Figure 1-2. Requesting an IP Address from the BootP Server (Group Access PVC)
5.
The upstream router sends the IP address and subnet mask to the BayStack
router in a BootP response message.
6.
The BayStack router assigns the IP address and subnet mask to any serial
interface that receives a BootP response.
7.
The BayStack router stores these IP addresses, along with the IP address of
the next-hop router, in RAM.
If more than one serial interface receives a BootP response, the BayStack
router assigns an IP address to each interface.
AN/ANH/ARN
Key
BOOTP response
BOOTP request
Upstream router
Circuit containing PVC 31, 32, 33 (for
virtual connections to the three routers)
Booting router 2 Booting router 3
BOOTP Client Interface Table:
DLCI 31 192.32.1.2
DLCI 32 192.32.1.3
DLCI 33 192.32.1.4
NPA0002A
Frame Relay
PVC 31
PVC 32
PVC 33
Seitenansicht 25