108 Chapter 6 Configuring resources — media bay modules
N0060606N0060606
GATM (Global Analog Trunk module)
These trunk modules can be adjusted to have static trunk parameters (pre-BCM 3.5 software), or to
allow the system to download new parameters when they become available (BCM 3.5 and later
software). If the trunk is set to the latter state, trunk parameters are downloaded every time the
module boots up, or when the parameters change while the module is working. You can also set
line and telephone impedance to either 600ohm or 900ohm for modules with downloadable
parameters. To set impedance, select Configuration > Telephony > Lines > Active Physical
Lines > Properties tab. Refer to the BCM200/400 4.0 Installation and Maintenance Guide
(N0060612) for details about the module.
Ports on Bus
Both types of modules have a Ports on Module table in the details panel. This panel shows the
state of the port that connects the module to the trunk line or system device.
Trunk modules - each port maps to an incoming line. Trunk port status is either equipped or
unequipped.
Station modules - each port maps to a connection to a system device (telephones, fax
machines, doorphone). For station modules, port status is either equipped (device connected)
or unequipped (no device connected). You can also determine what type of device is attached
to the port.
Bus 01 and 08 note: Bus 01 and 08 ports on bus are virtual ports, since they connect to services
supported by the MSC. These ports are used for such devices and services as IP telephones and
voice mail traffic.
Defining trunk module types and settings
MSC bus numbers assigned to a trunk module display module numbers under the Bus column that
correspond to the offset number set on the module DIP switches. For instance any trunk module
that has an offset of 0, appears in the Module 1 column, and so on to a maximum of four modules
(CTM4s/GATM4s).
The Module menu, that appears only under a Bus record that is configured for trunk modules,
allows you to configure line or loop provisioning for the module associated with a particular bus.
This record shows the number of lines or loops assigned to the module. It also provides the first
and last loop or line number. These settings are read-only.
Legacy
equipment
DECT Media Bay Module
(DECT)
DECT= 1 per bus, 4 loops,
supports 36 handsets
DECT (region-specific)
Table 20 Programmed Bus Types (Sheet 3 of 3)
Programmed
Bus Type Hardware unit Capacity
Available line types (some line
types are region-dependent)