Configuring ATM Services
9-4
ATM Signaling Parameter Descriptions
Use the following descriptions when editing the parameters in the ATM Signaling
Parameters window.
Parameter: Enable
Default: Enable
Options: Enable
| Disable
Function: Enables or disables ATM signaling on this interface.
Instructions: Accept the default, Enable, if you want signaling to remain enabled on
this interface. Set to Disable if you do not want signaling enabled on this
interface.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.2
Parameter: Max Number of SVC Applications
Default: 20
Range: 1 to 32767
Function: Identifies the maximum number of service access points (SAPs) allowed
for this circuit. The number of SAPs corresponds to the number of LAN
emulation or IP (RFC 1577) clients allowed for the circuit.
Instructions: Accept the default, 20, or enter a value from 1 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.6
Note: When you disable signaling on the interface, the ATM Service Record
Parameters window automatically sets the Data Encapsulation Type
parameter to LLC/SNAP and the Virtual Connection Type parameter to PVC.