Editing ATM Signaling and ILMI Parameters
9-11
Parameter: T316c
Default: 120
Range: 1 to 720
Function: Defines the Restart Request Sent on Channel timer value (in seconds).
This timer begins when the circuit sends a RESTART message to the
network. The circuit uses the RESTART message to return this individual
VC on the interface to the idle condition.
The Restart Request Sent on Channel timer stops when the circuit
receives a RESTART ACKNOWLEDGE message from the network.
If the timer expires before the circuit receives a RESTART
ACKNOWLEDGE message, the circuit can transmit as many RESTART
messages as specified with the Num Restarts Permitted parameter (refer
to the parameter description later in this section). If the circuit still does
not receive a response, the circuit enters the Null state until the
appropriate maintenance action is taken.
Instructions: Accept the default, 120, or enter a value from 1 to 720.