Editing ATM Signaling and ILMI Parameters
9-23
Parameter: Poll Timer
Default: 7
Range: 1 to 120
Function: Defines the Service Specific Connection Oriented Protocol (SSCOP) Poll
timer value (in tenths of a second). This value sets the allowable time
between Poll Protocol Data Unit (PDU) transmissions.
The Poll timer ensures that the receiver continues to return a solicited
status (STAT) PDU to the sender on a regular basis. The timely receipt of
STAT PDUs restarts the Poll timer and allows for more efficient
transmission error recovery.
Instructions: Accept the default, 7, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.9
Parameter: Keep Alive Timer
Default: 20
Range: 1 to 120
Function: Defines the SSCOP Keep Alive timer value (in tenths of a second). This
value sets the allowable time between POLL PDU transmissions if there
are no pending Sequence Data (SD) PDUs.
The Keep Alive timer is generally greater than the Poll timer and greater
than the length of one round-trip delay.
Instructions: Accept the default, 20, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.10