Editing ATM Signaling and ILMI Parameters
9-9
Parameter: T310
Default: 10
Range: 1 to 60
Function: Defines the Call Proceeding Received timer value (in seconds). This timer
begins when the circuit receives a CALL PROCEEDING message from
the network.
If the signaling does not receive a CONNECT or RELEASE message
before this timer expires, it clears the connection for that virtual circuit.
Instructions: Accept the default, 10, or enter a value from 1 to 60.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.28
Parameter: T313
Default: 4
Range: 1 to 24
Function: Defines the Connect Sent timer value (in seconds). This timer begins
when the circuit sends a CONNECT message to the network.
The Connect Sent timer stops when the circuit receives a CONNECT
ACKNOWLEDGE message from the network (indicating the completion
of the ATM connection for that interface).
If the timer expires before the circuit receives a CONNECT
ACKNOWLEDGE message, the circuit clears the connection.
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.29