Editing ATM Signaling and ILMI Parameters
9-13
Parameter: T398
Default: 4
Range: 1 to 24
Function: Defines the Drop Party Sent timer value (in seconds). This timer applies
to multipoint connections only and begins when the circuit sends a DROP
PARTY message to a party (the receiver of the message) on the network.
The Drop Party Sent timer stops when the circuit receives a DROP
PARTY ACKNOWLEDGE message (indicating that the endpoint used
for the party has been released), or a RELEASE message (indicating that
the endpoint used for the party has been released and there are no
remaining parties).
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.34
Parameter: T399
Default: 14
Range: 1 to 84
Function: Defines the Add Party Sent timer value (in seconds). This timer applies to
multipoint connections only and begins when the circuit sends an ADD
PARTY message to a party (the receiver of the message) on the network.
The Add Party Sent timer stops when the circuit receives an ADD PARTY
ACKNOWLEDGE message (indicating the connection to the party),
ADD PARTY REJECT message (indicating the inability to add the party),
or a RELEASE message (indicating the inability to add the party and the
absence of any remaining parties).
If the timer expires before the circuit receives an ADD PARTY
ACKNOWLEDGE, ADD PARTY REJECT, or RELEASE message, the
circuit clears the party.
Instructions: Accept the default, 14, or enter a value from 1 to 84.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.35