
Editing ATM Signaling and ILMI Parameters
9-25
Parameter: Max Connection Control
Default: 4
Range: 1 to 20
Function: Defines the SSCOP Maximum Connection Control (CC) value. This
value sets the maximum number of times the sender can transmit a BGN,
END, RS, or ER PDU.
Instructions: Accept the default, 4, or enter a value from 1 to 20.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.13
Parameter: Max PD Before Poll
Default: 25
Range: 1 to 120
Function: Defines the SSCOP Maximum Poll Data (PD) value. This value sets the
maximum value of the poll data state variable before transmitting a POLL
PDU. The poll data state variable increments upon transmission of a
Sequenced Data (SD) PDU and resets to zero upon transmission of a
POLL PDU.
Instructions: Accept the default, 25, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.14
Parameter: Max STAT PDU Elements
Default: 67
Range: Odd integers from 3 to 119
Function: Defines the SSCOP Maximum STAT value. This value sets the maximum
number of list elements allowed in a STAT PDU.
The sending device uses the value of this parameter for segmentation
purposes. When the number of list elements exceeds the Max STAT value,
the STAT message segments. As a general rule, the default value, 67,
causes the STAT PDU to fill six ATM cells using AAL 5.
Instructions: Accept the default, 67, or enter an odd integer from 3 to 119.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.15
Kommentare zu diesen Handbüchern