show ds1e1
2-209
alerts
Displays all DS1E1 logical lines that are enabled but not up. Use this display to identify
the logical lines that are not working. The table includes the following information:
Slot Slot identifier.
Conn Connector identifier.
Log Line Logical line number for this line.
Line Type Type of line in use: Unframed T1, ESF, SF, E1, E1CRC, E1MF,
E1CRCMF, or Unframed E1.
Circuit Name of the circuit associated with this line.
State State of the logical line as follows: Up, Down, Init (initializing),
LMI Wait, Loopback, Dying, Dead, or Not Pres (not present).
Line Number Line number for this line; assigned during configuration. This line
number uniquely identifies this interface and is not equal to any of
the line numbers assigned to logical lines configured through this
port.
WAN Protocol WAN protocol enabled on this interface: ATM, FRM RLAY (Frame
Relay), LAPB, PASSTHRU, PPP, SMDS, WF STND (Wellfleet
Standard), or X.25. Wellfleet Standard is a proprietary protocol
used between two Bay Networks routers. Based on the CCITT
HDLC (High-level Data Link Control) protocol, Wellfleet Standard
provides LLC1 (connectionless, datagram) service.
Rate Adapt Rate adaption — the number of bits and their positions within the
timeslot, as follows:
• 64K – Uses all 8 bits in the timeslot.
• 56K MSB – Uses 7 of the 8 bits in the timeslot; does not use the
most significant bit.
• 56K LSB – Uses 7 of the 8 bits in the timeslot; does not use the
least significant bit.