Seitenansicht 620
show sync
2-569
Sample Display – show sync receive
SYNC Module Receive Errors:
---------------------------
Bad Runt Frame Frames Overflow
Slot Conn Circuit Frames Frames Rejects Too Long Frames
---- ---- ------- --------- --------- --------- --------- ---------
5 1 S51 0 7 0 0 0
5 2 S52 1 1 0 0 0
2 entries in table.
sample
[
<
period in seconds
>
] [circuit
<circuit name>
]
Displays data sampled from SYNC over a period of 10 seconds. You can change the
number of seconds over which you want to sample the data, and you can display sampled
data for a specific circuit only. The table includes the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Rx Frames Number of frames received on this line.
Tx Frames Number of frames sent on this line.
Rx Lack of Resources Number of packets received and discarded because of lack of
resources; for example, buffers.
Tx Lack of Resources Number of transmit packets discarded because of lack of resources;
for example, buffers.