Avaya Using Technician Interface Scripts Bedienungsanleitung Seite 295

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 788
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 294
show e1
2-243
Sample Display – e1 alerts
E1 Modules on Alert:
--------------------
HDB3 Clock
Slot Conn Circuit Support Mode MiniDacs Configuration
---- ---- ------- -------- -------- -------------------------------
Found 0 matches out of 2 entries in table.
MiniDacs Configuration Function assigned to each of 31 E1 channels (timeslots). The table
shows these functions in a string of 31 characters, one character
per timeslot. The characters and their meaning are as follows:
1Assigns the timeslot to the first HDLC controller (Circuit 1).
2Assigns the timeslot to the second HDLC controller
(Circuit 2).
DAssigns the timeslot to data passthrough (HDLC controller
to HCLC controller).
IAssigns the timeslot to idle.
VAssigns the timeslot to voice passthrough (HDLC controller
to HCLC controller).
For example, the sample display for the base command shows
the MiniDacs Configuration as:
11111111IIIIIIII11111111IIIIIII.
This string shows that timeslots 1 - 8 and 17 - 24 are assigned to
the first HDLC controller (1) and timeslots 9 - 16 and 25 - 31 are
idle (I).
Seitenansicht 294
1 2 ... 290 291 292 293 294 295 296 297 298 299 300 ... 787 788

Kommentare zu diesen Handbüchern

Keine Kommentare