Avaya Using Technician Interface Scripts Bedienungsanleitung Seite 342

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 788
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 341
Using Technician Interface Scripts
2-290
Sample Display – show hssi receive errors
HSSI Module Receive Errors:
-----------------------------
Frames
Slot Conn Circuit CRC Errors Overruns Aborts Too Long
---- ---- ------- ---------- ---------- ---------- ----------
3 1 H31 0 0 0 0
1 entry in table.
sample [
<period in seconds>
] [circuit
<circuit name>
]
Displays data sampled from HSSI over a period of 10 seconds. You can change the number
of seconds over which you want to sample the data, and you can display sampled data for
a specific circuit only. The table includes the following information:
Overrun Errors Number of frames received that were aborted due to the memory
bandwidth of the FIFO buffer overrunning during DMA.
Aborts Number of frames received with abort errors.
Frames Too Long Number of frames received that exceeded the MTU size.
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Rx Frames Number of frames received on this line.
Tx Frames Number of frames sent on this line.
Rx Lack of Resources Number of packets received and discarded because of lack of
resources; for example, buffers.
Tx Lack of Resources Number of transmit packets discarded because of lack of resources;
for example, buffers.
Seitenansicht 341
1 2 ... 337 338 339 340 341 342 343 344 345 346 347 ... 787 788

Kommentare zu diesen Handbüchern

Keine Kommentare