Using Technician Interface Scripts
2-570
Sample Display – show sync sample
SYNC Sampled Data over 10 seconds
----------------------------------
Rx Tx Rx Lack of Tx Lack of
Slot Conn Circuit Frames Frames Resources Resources
---- ---- ------- ---------- ---------- ---------- ----------
3 1 S31 11 12 0 0
1 entry in table.
Sample Display – show sync sample circuit s31
SYNC Sampled Data over 5 seconds
----------------------------------
Rx Tx Rx Lack of Tx Lack of
Slot Conn Circuit Frames Frames Resources Resources
---- ---- ------- ---------- ---------- ---------- ----------
3 1 S31 5 6 0 0
Found 1 matches out of 1 entry in table.
stats [circuit
<circuit name>
]
Displays SYNC input/output statistical information for all SYNC modules or for a specific
circuit. The table contains the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Receive Bytes Number of octets received without error.
Receive Frames Number of frames received without error.
Transmit Bytes Number of octets transmitted without error.
Transmit Frames Number of frames transmitted without error.
Total Errors Total number of errors of all types.