Using Technician Interface Scripts
2-274
Sample Display – show fr stats
Frame Relay PVC Statistics
--------------------------
Sent Received
Line.LLIndex.DLCI Frames Octets Frames Octets Discard Drops
----------------- ---------- ---------- ---------- ---------- -------- -------
-
202101.0.100 0 0 0 0 0 0
202101.0.200 0 0 0 0 0 0
202101.0.300 0 0 0 0 0 0
202102.0.1023 127 1651 0 0 0 0
202103.0.0 127 1651 0 0 0 0
202104.0.0 127 1778 0 0 0 0
Total entries: 6
stats circuit [
<circuit name>
]
Displays statistics associated with all Frame Relay circuits or a specified circuit. Because
of multiline, a Frame Relay circuit can have several Frame Relay interfaces associated
with it. Circuit statistics count the number of frames dropped or discarded at the circuit
level. This includes both the main-level circuit and the circuits associated with hybrid and
direct PVCs.
Sample Display – show fr stats circuit
Frame Relay Circuit Statistics
------------------------------
Circuit Discards Drops
---------------- -------- --------
S21 0 0
202101.0.400 0 0
202101.0.500 0 0
Total entries: 3