Sample Display – show hssi stats
HSSI Module I/O Statistics:
---------------------------
Receive Receive Transmit Transmit Total
Slot Conn Circuit Bytes Frames Bytes Frames Errors
---- ---- ------- ---------- ---------- ---------- ---------- ----------
3 1 H31 600808237 10617073 3692023 141294 0
1 entry in table.
system errors [circuit
<circuit name>
]
Displays statistical information about system errors for all circuits or for a specific circuit.
The table includes the following information:
Transmit Frames Number of frames transmitted without error.
Total Errors Total number of errors of all types.
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Rx Ring Errors Number of errors that the DMA controller has detected while
processing the receive ring.
Tx Ring Errors Number of errors that the DMA controller has detected while
processing the transmit ring.
Internal Op Errors Number of internal operation errors.
Host Errors Number of parity errors occurring while the host driver accesses a
register on the DMA controller. Host errors may indicate faulty
hardware. If this count exceeds five, call your customer service
representative.
Port Errors Number of DMA controller port-operation errors. Port errors may
indicate faulty hardware. If this count exceeds five, call your
customer service representative.