Avaya Using Technician Interface Scripts Bedienungsanleitung Seite 492

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 788
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 491
Using Technician Interface Scripts
2-440
bad packets
Displays the number of bad packets received over each circuit and the first 16 bytes of the
last bad packet. If the number of bad packets is above zero, then the PPP circuit is
receiving misformed packets or packets meant for other protocols. The hexadecimal
display of the last bad packet will show the kind of packet being received. The display
includes the following information:
Sample Display – show ppp bad
PPP Circuit: Bad Packet Information
-----------------------------------
# of Bad
Circuit Packets Last Bad Packet
-------- -------- --------------------
S31 0 None
S32 0 None
2 Entries found.
bridge {configured | negotiated}
The display includes the following information:
Circuit Name of the circuit receiving the bad packets.
Number of Bad Packets Number of bad packets received at this point.
Last Bad Packet First 16 bytes of the last bad packet.
configured Displays the state of the Bridge NCP and the kind of bridged
frames that are enabled.
Circuit Name of the circuit the protocol runs on.
State State of the Bridge NCP — either Disabled, or if Enabled, any of
the states listed under the alerts command.
Seitenansicht 491
1 2 ... 487 488 489 490 491 492 493 494 495 496 497 ... 787 788

Kommentare zu diesen Handbüchern

Keine Kommentare