Customizing SVCs
308624-14.10 Rev 01
5-19
Disconnect Timer
The disconnect timer indicates the number of seconds allowed from the time the
router sends a disconnect message and receives a release message back. If a
timeout occurs, the router sends a release message and enters the release request
state. The timer is not restarted.
To set the disconnect timer, navigate to the signalling prompt (for example,
box;
serial/1/2; frame-relay/1/2; signalling/3/2
) and enter:
disconnect-timer
<integer>
integer
is the number of seconds allowed. The value can be from 20 to 90 seconds.
The default is 30.
For example, the following command line sets a timer of 45 seconds:
signalling/3/2#
disconnect-timer 45
signalling/3/2#
Release Timer
The release timer indicates the number of seconds allowed for call clearing
initiated by the other end of the connection or when the disconnect timer expires.
If a timeout occurs, the router retransmits the release message and restarts the
timer. If the timer expires a second time, the router clears the call.
To set the release timer, navigate to the signalling prompt (for example,
box;
serial/1/2; frame-relay/1/2; signalling/3/2
) and enter:
release-timer
<integer>
integer
is the number of seconds allowed. The value can be from 2 to 90 seconds.
The default is 4.
For example, the following command line sets a timer of 45 seconds:
signalling/3/2#
release-timer 45
signalling/3/2#