Customizing Frame Relay Interfaces
308624-14.10 Rev 01
3-3
Using the BCC
To specify a management protocol, navigate to the dlcmi prompt (for example,
box; serial/1/2; frame-relay/1/2; dlcmi) and enter:
management-type
<value>
value
can be:
none
lmi
annex-d
(the default)
annex-a
lmi-switch
annex-d-switch
annex-a-switch
For example, the following command line changes the management type from
Annex D Switch to LMI Switch:
dlcmi/1/2# management-type lmi-switch
dlcmi/1/2#
Using Site Manager
To specify a management protocol, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Interfaces
. The Frame Relay Interface List window
opens.
4. Set the
Mgmnt Type
parameter. Click on
Help
or the see the parameter description
on page A-5.
5. Click on
Apply
.
(continued)