Customizing Frame Relay Interfaces
308624-14.10 Rev 01
3-7
Using Site Manager
To specify the address type and length, complete the following tasks:
Monitoring the Connection
You can monitor the status of your frame relay network connection by setting:
Time intervals for the router to send messages that verify the integrity of the
link
The number and frequency of error messages that can occur before the
connection terminates
Polling Interval
The polling interval specifies the amount of time between status inquiry messages
that the router transmits. Status inquiry messages cause a network to respond with
a link integrity verification message or full status message.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Interfaces
. The Frame Relay Interface List window
opens.
4. Set the following parameters:
•Address
Address Length
Click on
Help
or see the parameter
descriptions beginning on page A-6.
5. Click on
Apply
.
6. Click on
Done
. You return to the Frame Relay Circuit
Definition window.
7. Click on
Done
. You return to the Configuration Manager
window.