Customizing Backup Circuits
117353-B Rev. 00
11-23
Using Site Manager
To delete a backup circuit’s schedule:
Removing PPP or Frame Relay Backup Service
The following sections explain how to remove dial backup circuits.
Using the BCC
To delete a backup service, navigate to the backup circuit prompt for the interface
that you want to delete and enter:
delete
For example:
backup-circuit/8/5/1# delete
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Backup Circuits
. The Backup Circuits menu opens.
3. Choose
PPP
or
Frame Relay
. The Primary Circuit Definition window or
FR Primary Interface Definition window
opens.
4. Click on
Schedule
. The first Circuit Time of Day Schedule
window opens.
5. Select a schedule entry to be deleted.
6. Click on
Delete
. Site Manager removes the entry.
7. Click on
OK
. You return to the completed Circuit Time
of Day Schedule window.
8. Click on
Done
. You return to the Primary Circuit
Definition or FR Primary Interface
Definition window.
9. Click on
Done
. You return to the Configuration Manager
window.
Seitenansicht 268