Dial Service Parameters
117353-B Rev. 00
A-35
Parameter: Retry Delay
Path: Dialup > Demand Circuits > Demand Pools > PPP or FR Circuits >
PPP or FR Demand Circuits
Default: 3 seconds
Options: 1 to 60 seconds
Function: Determines how long the router waits between each retry attempt before trying
to reestablish the circuit.
Instructions: Enter the amount of time that you want the router to wait before trying the next
line in the pool. The amount of time you choose depends on the time it typically
takes the network to recover.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.27
Parameter: Connection Mode
Path: Dialup > Demand Circuits > Demand Pools > PPP or FR Circuits >
PPP or FR Demand Circuits
Default: Collision Master
Options: No Dial | Collision Master | Collision Slave
Function: Determines the role of each router when two routers try to establish a demand
circuit with one another. Both routers in a demand configuration can initiate a
call. This parameter determines which router places the call first to avoid
continual collisions.
Instructions: To avoid continual collisions, configure one router as Collision Master and the
other as Collision Slave. To ensure that a router receives calls, but never
initiates calls, enter No Dial. Calls are then made only in one direction.
If this circuit is part of an unnumbered demand circuit group, the router
automatically sets this parameter to No Dial because a circuit in a demand
circuit group cannot initiate a call.
If you are configuring a bandwidth pool for this circuit, and this router is the
monitor router, you can select Collision Master or Collision Slave.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.28