Configuring Dial Services
A-70
117353-B Rev. 00
Parameter: Interface Type
Path: Dialup > Backup Circuits > Frame Relay > FR Primary Interface Definition >
Intf. Type > FR Interface Slot <n>,<port>
Default: Normal
Options: Normal
|
Primary/Shared
|
Primary/Secondary
Function: Specifies whether this leased circuit uses dial backup service. For a standard
leased circuit, the router does not provide a backup circuit if it fails. For a
primary circuit, the router provides a backup circuit.
Instructions: Select one of the following options:
Normal -- Indicates that there is no backup service for this circuit.
Primary/Shared -- Enables backup service and instructs the router that the
backup circuit should inherit the primary circuit’s configuration.
If you select this option, Site Manager displays a dialog box asking if you want
the primary circuit’s PVCs duplicated on the backup circuit.
Select Ye s to create a duplicate set of PVCs with the same DLCI numbers as
the primary circuit. This is useful if you want the same DLCI numbers going
to the same destination.
Select No to configure unique PVCs for the backup circuit. This option is
useful if you do not want to back up all of the primary’s PVCs. By limiting
the number of backup PVCs, you can reduce line costs.
Primary/Secondary -- Enables backup service and instructs the router that the
backup circuit should use its own configuration. The backup circuit does not
adopt the primary circuit’s configuration.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.33