Configuring Dial Services
A-12
117353-B Rev. 00
Parameter: Modem Command String
Path: COM Connector > Edit Modem > Sync/Async Modem Interface or Async
Line Media Type
OR
Dialup > Pools > Demand/Backup/Bandwidth on Demand Pools >
Add > Demand/Backup/Bandwidth on Demand Pool Configuration > OK >
Lines Definition > COM Connector > Choose Wan Serial Interface Type >
OK > Sync or Async Line Media Type
Default: None
Options: Any valid modem command string (Raise DTR and V.25bis only).
Function: Enables you to test and modify the configuration of your modem. For
example, if you want to change the speed of your modem, you can enter a
command string to do this. Also, if you are having trouble placing calls, enter
a string to test whether the modem responds.
Instructions: Enter a command string that your modem supports.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.8.13.1.4
Parameter: Modem Init String
Path: COM Connector > Edit Modem > Async Hayes Modem Interface
Default: AT& F
Options: An AT modem command string, which is an ASCII text string from 3 to 34
characters.
Function: For asynchronous interfaces only, this parameter specifies the modem
initialization string the router sends to the modem. This command string takes
precedence over factory default commands.
Instructions: Enter an AT command string that the modem should use to make calls. You
must enter a value for this parameter if you selected Custom as the modem type.
If you fail to enter a value, Site Manager prompts you to do so. Appendix E
provides a summary of AT commands for the ARN. Refer to the manual for
your modem for valid AT commands. Entering an invalid command may disable
the modem. If the modem does not initialize, you may need to change the
asynchronous baud rate. To do this, click on the COM connector and select Edit
Line. Modify the value of the asynchronous baud rate.
MIB Object ID: 1.3.6.1.4.1.18.3.4.29.1.1.9